北京  ■ 深圳 ■ 上海  ■ 成都  ■ 重庆  ■ 浙江
经过数据恢复工程师的努力研究,已搞清楚了XFS文件系统的结构层。如果有基于XFS的NAS或LINUX数据出现问题,已有很大把握了。基于XFS数据恢复的软件已经完工。
站 内 搜 索
    
热 点 文 章
PC3000使用说明
关于硬盘坏道(绝对有收获) 
pc3000译文
U盘故障的详细维修方法! 
硬盘零磁道与分区表的修复
pc3000处理常见故障的一些方
推 荐 文 章
Hrt修复磁盘缺陷
pc3000处理常见故障的一些方
硬盘容量限制问题的形成以及
关于硬盘坏道(绝对有收获) 
20个美钻维修心德(1.22版)
Disk Genius V2.0 Beta 0219
FUJITSU盘故障表现
FUJ维修资料
最 新 文 章
中国地震局地质研究所
中央电视台新闻评论部
秦皇岛温先生
北京蔡小姐
北京米先生
教育部学位中心
湖北谢先生
北京华光民天工贸服务有限公
联 系 我 们
北京北亚数据恢复中心
地址:北京市海淀区学院南路68号吉安大厦C座(汇智楼)528室
电话:(010)51280825
手机:13522617215 (张先生)
电子邮件:zymail@vip.sina.com
QQ:34000588(请叙述理由)
您现在的位置:

首页>>HRT技术文章>>正文

HRT的Seagate Drives U6英文说明书

作者: 来源: 日期:2006-03-26 01:51:06  点击次数:
The authors warn that the use of a utility  "HDD Repair  Tool for Seagate U6 "  is permissible ONLY with accumulators  Seagate U6.
An attempt at the application of a utility on the accumulators of other models can lead to their  irreversible spoiling!

BEFORE beginning the repair of accumulator, immediately after the start of utility, obyazatel'-
but it is necessary to preserve in the archive its contained flesh - PZU and disk moduli.
? flesh - PZU can be counted by means of dialogue  Actions->.Flash operations;
? disk moduli can be counted by means of dialogue  Service - > CP operations.

Look the detailed description of work with these dialogues in the appropriate divisions of documentation.

Main menu
With the pushing of the right knob of "mouse", the program issues on the screen the main menu, the hierarchy of points of which is given below:
 
The designation of the points of menu will be described below.
Testing the accumulator
General information
Upon the entering of nakopitel 4 in the repair should be compulsorily thoroughly looked around its printed-circuit board to the object of the visible malfunctions of electronic components, and so to the object of the possible substitution of pay, since the printed-circuit boards of accumulators  Seagate U6  on to their of forms - to factor they coincide with the printed-circuit boards of accumulators  Seagate U4, Seagate U8, Seagate V8, Seagate U10  and  Seagate U5.  During the detection of substitution should be replaced the pay.
So should be verified by tester resistance between the common wire and the power buses  of +.shchV  and  +.y2V:
? on the power bus  of +.y2V  resistance must be about  71  kљ;
? on the power bus  of +.shchV  resistance must be about  1.4  kљ.

We further connect accumulator to pay  HRT  and start utility. Accumulator must leave into the readiness - in the field of the "window of light-emitting diodes" must ostat's 4 "burn" only flags  DRDY  and  DSC.

The work of utility with the accumulators, which do not emerge into the readiness on  Ata- to interface, is impossible!  This is caused by the limitations of the microprogram of the very of nakopitel 4.

After the start of utility will appear the window, in which will be represented kha rakteristiki of accumulator.
 
Focus attention, that the complete name of the microprogram of accumulator, printed out in field  Family code,  contains  5  numbers, grouped into  3  fields.  However, gluing on the housing of accumulator contains only the first two fields of the version of microprogram in the line  "Firmware".
Special features of testing accumulators  Seagate U6
Unfortunately, all accumulators  Seagate U for a series do not permit implementation of access through  Ata- interface to the surface of disk directly in the physical coordinates. Firm herself  Seagate  achieves testing accumulators with the aid of the special version of microprogram, loaded before the plant testing into flesh - PZU of nakopitel 4. After the end of testing microprogram into flesh - PZU they substitute by the user version, which does not have the commands of access to the physical surface.

本新闻共9页,当前在第1页  1  2  3  4  5  6  7  8  9  


上一篇:HRT的Seagate Drives U8, V8, U10英文说明书
下一篇:HRT的Seagate Drives Ux英文说明书
相关文章
Copyright 2005 - 2006 版权所有 北亚数据恢复中心
全国统一客服电话:4006-505-808 或 800-810-5880
地址:北京市海淀区学院南路68号吉安大厦C座(汇智楼)528
申明:本网站所有关于硬盘数据恢复硬盘维修的资料及工具全部来自网络,如有侵权,请通知我们,我们马上做出处理-北亚数据恢复中心。